What is a hydronic system air removal? It is the process of getting rid of air from your heating pipes and radiators. Can I purge air from my boiler myself? Yes, you can. It takes time and care. Why do I hear gurgling noise in heating pipes? This sound often means air is trapped in your system. Boiler no heat due to air? Yes, air pockets can stop hot water from flowing, leaving parts of your home cold. Circulator pump air issues? Air can make your pump work harder or even stop it from moving water. This guide will show you how to purge air from a boiler with zone valves. It will help your heating system work its best.
Image Source: i.sstatic.net
Grasping Air Issues in Hydronic Heating Systems
Your home’s heating system uses water. This is called a hydronic system. Hot water flows through pipes. It then goes to radiators or baseboards. These heat your rooms. Air is a big problem for these systems. Air should not be in the pipes.
Air acts like a bubble. It gets stuck. This bubble blocks the hot water. The water cannot flow well. This stops heat from reaching all areas. You might feel some rooms are cold. This is a common sign of air.
Air can also cause noise. You might hear gurgling noise in heating pipes. It sounds like water running inside the walls. This is air moving through the water. It can be annoying. It also tells you there is air in the system.
Air makes your boiler work harder. Your circulator pump pushes water. If air is present, the pump struggles. It tries to push water and air. This wastes energy. It can also damage the pump over time. So, circulator pump air issues are serious. They can lead to costly repairs.
Removing air is important. It makes your system quiet. It makes it work better. It saves energy. It also helps your heating parts last longer. This process is called hydronic system air removal. It ensures your home stays warm and cozy.
Recognizing Signs of Trapped Air
How do you know if you have air in your system? There are clear signs. Pay attention to them.
Common Signs of Air:
- Cold Radiators or Baseboards: Some parts of your heating system may be cold. Other parts might be warm. This means hot water is not reaching the cold areas. Air is likely blocking the path.
- Noises: You hear bubbling, hissing, or gurgling sounds. These noises come from your pipes. They are often loudest when the heat first turns on. This is air moving with the water.
- Reduced Heat Output: Your home does not get as warm as it should. The boiler runs often. But the heat does not spread well. This can be a sign of boiler no heat due to air.
- Frequent Boiler Cycling: The boiler turns on and off too much. This can happen if the system has air. Air makes the boiler think it needs more heat.
- High Energy Bills: Your heating bills go up. But your home is not warmer. An air-filled system works less efficiently. It uses more fuel to do the same job.
If you see these signs, you likely have air. It is time to purge your system. This means getting the air out.
Crucial Components for Air Removal
Your heating system has parts that help with air. Knowing these parts is key.
- Air Vent: Many boilers have an automatic air vent. It is usually at the top of the boiler. It lets small amounts of air out on its own.
- Expansion Tank: This tank handles changes in water volume. Water expands when it heats up. The tank gives this extra water a place to go. It also helps keep system pressure steady. A bad tank can cause air problems.
- Pressure Relief Valve: This valve is a safety device. It opens if the system pressure gets too high. It lets out water to lower the pressure.
- Pressure Gauge: This shows the water pressure in your system. You need to watch this when purging air.
- Temperature Gauge: This shows the water temperature.
- Fill Valve / Pressure Reducing Valve: This valve adds water to your system. It keeps the pressure at the right level. It often connects to your home’s main water line.
- Boiler Drain Valve: This valve lets you drain water from the boiler. It is usually at the bottom.
- Zone Valves: These valves control heat to different parts of your home. Each zone valve controls one heating zone. Your home might have two zones, three zones, or more.
- Purge Valves / Drain Cocks: These are small valves. They are often found near zone valves or at the ends of heating loops. You use them to force air out.
- Circulator Pump: This pump moves hot water through your pipes. Circulator pump air issues can hurt its performance.
- Hydronic Air Separator: This is a special device. It is placed near the boiler. Its main job is to remove air from the water. Water flows through it. Air bubbles collect in it. Then, an automatic air vent lets the air out. The hydronic air separator purpose is to catch air before it spreads. This is a very helpful part to have.
Knowing where these parts are helps you purge air well.
Safety First: Important Preparations
Before you start, safety is a must. You are working with hot water and electricity.
What You Will Need:
- Garden Hose: About 10-15 feet long.
- Bucket: To catch water.
- Wrench or Pliers: To open valves if they are stiff.
- Towels or Rags: For spills.
- Gloves: To protect your hands.
- Flashlight: To see in dark areas.
- A Helper: Two sets of hands make this job easier.
Pre-Purge Checklist:
- Turn Off the Boiler Power: Go to your electrical panel. Find the switch for the boiler. Turn it off. This stops the boiler from firing. It also stops the circulator pump. This is very important. You do not want hot water to rush through while you are working.
- Let the System Cool Down: Wait for the water to cool. Hot water can scald you. It also holds more air. Cold water holds less air. This makes purging easier. This might take an hour or more.
- Find Your Fill Valve: This valve adds water to the system. You need to keep it open or slightly open during purging. It often has a lever or a knob. It may also be called a pressure reducing valve.
- Check System Pressure: Look at your pressure gauge. Note the current pressure. For a two-story home, pressure is often between 12-18 PSI when cold. You might need to raise it slightly during purging.
- Locate All Purge Points: Find the boiler drain valve. Find the drain cocks or purge valves for each zone. These are often near the zone valves. They might also be at the lowest point of each heating loop. Find air vents on radiators or baseboards too.
- Attach Hoses: Connect your garden hose to the boiler drain valve. Put the other end into a large bucket or lead it to a floor drain. If using multiple purge points, you will move the hose.
Take your time with these steps. Being ready makes the purging process safer and simpler.
The General Purging Procedure: Step-by-Step
This is the main zone valve purging procedure. We will go zone by zone. This is the best way to get all the air out. Bleeding multiple heating zones means purging one zone at a time. This pushes air out more effectively.
Step 1: Set Up for Purging
- Boiler Off: Ensure the boiler is still off.
- Hose Connected: Confirm the hose is securely on the boiler drain valve. The other end should be in a bucket or drain.
- Fill Valve Position: For many systems, you want to open the fill valve fully. This lets fresh water flow in quickly. It helps push air out. Watch your pressure gauge. It will go up. This is fine for now. You want to create a strong flow.
- Close All Zone Valves EXCEPT ONE: This is very important for bleeding multiple heating zones. Each zone valve controls a separate part of your home. You need to work on one zone at a time. Find all your zone valves. Close them all. Only leave open the valve for the zone you want to purge first.
Step 2: Purge the First Zone (Zone 1)
- Open Zone Valve: Make sure only the zone valve for Zone 1 is open. All other zone valves must be closed.
- Find Purge Point for Zone 1: Each zone usually has a dedicated purge valve or drain cock. This is often on the return pipe for that zone, close to the boiler or zone valve. Attach your hose to this purge valve if it’s different from the main boiler drain. If it’s the same, then you just use the main drain.
- Open Purge Valve for Zone 1: Slowly open the purge valve for Zone 1. Water will start to flow out.
- Watch and Listen: At first, you will hear gurgling and spitting. This is air coming out. Water will be bubbly. Keep letting water flow until it runs clear and smooth. No more air bubbles. No more gurgling.
- Check Pressure: While purging, watch your pressure gauge. It might drop. If it drops too low (below 12 PSI), close the purge valve for a moment. Let the fill valve add more water. The pressure will rise. Then, open the purge valve again. Repeat until all air is out of this zone.
- Close Purge Valve for Zone 1: Once the water is clear and air-free, close the purge valve tightly.
- Close Zone Valve for Zone 1: Now close the zone valve for Zone 1. This traps the purged water inside.
Step 3: Purge Subsequent Zones (Zone 2, Zone 3, etc.)
Repeat Step 2 for each remaining zone.
- Open Next Zone Valve: Open only the zone valve for Zone 2. Ensure all other zone valves (including Zone 1’s) are closed.
- Find and Open Purge Valve for Zone 2: Locate the specific purge valve for Zone 2. Open it slowly.
- Purge Until Clear: Let water run until it is clear and smooth, with no air bubbles. Watch the pressure. Add water if needed.
- Close Valves: Close the purge valve for Zone 2. Then close the zone valve for Zone 2.
Continue this process for every single heating zone in your home. This might take some time, especially for a large home with many zones. Patience is key for proper boiler air lock troubleshooting.
Step 4: Final Steps
- Close Boiler Drain Valve: After purging all zones, close the main boiler drain valve tightly. Remove the hose.
- Adjust Fill Valve: If you opened the fill valve fully, slowly close it. Set it back to its normal automatic position. Most systems have a lever that lets you set it to ‘auto’ or ‘manual’. Make sure it’s in ‘auto’.
- Check System Pressure: Once all valves are closed, check the pressure gauge again. It should be at the correct cold pressure for your system (e.g., 12-18 PSI). If it’s too low, open the fill valve slightly to raise it. If it’s too high, you might need to release a little water from a drain valve until it’s correct.
- Turn Boiler Power Back On: Go back to your electrical panel. Turn the boiler switch back on.
- Monitor System: Turn on your thermostat. Let the boiler run. Listen for any gurgling noises. Feel your radiators and baseboards. They should all get warm now. If you still hear noises or have cold spots, you may need to re-purge.
Purging Specific Heating Components
Sometimes, air gets stuck in specific parts of your system. Here’s how to handle them.
Removing Air from Hot Water Baseboards
Hot water baseboards can trap air easily. Air rises. Baseboards are often high up on walls.
- Find Bleed Screws: Many baseboard units have a small bleed screw at one end. It looks like a small valve or a slotted screw. It might be under a cap.
- Use a Radiator Key or Screwdriver: You need a special key or a flathead screwdriver to open these.
- Place a Rag: Put a rag or small bucket under the bleed screw. This will catch any water.
- Open Slowly: Turn the bleed screw slowly. You will hear a hiss. This is air coming out.
- Close When Water Flows: Keep it open until water starts to flow steadily. There should be no more air. Then, close the screw tightly.
- Repeat: Do this for every baseboard unit in the cold zone. This is key for removing air from hot water baseboards.
Cold Zone Radiator Purging
If you have traditional radiators, they also have bleed valves. These are usually on the side or top.
- Locate Bleed Valve: Find the small valve on the radiator.
- Use Radiator Key: Use a radiator key to open it.
- Catch Water: Have a rag or small bowl ready.
- Open Until Air Stops: Turn the key slowly. Air will hiss out. Once water starts to come out in a steady stream, close the valve.
- Check All Radiators: If one radiator is cold, check all radiators in that cold zone radiator purging process. Air might be in several.
Table: Common Bleed Valve Types
Bleed Valve Type | Appearance | Tool Needed | Notes |
---|---|---|---|
Manual Air Vent (Radiator) | Small, round knob or slotted screw on radiator | Radiator key or flathead screwdriver | Most common on old radiators. |
Automatic Air Vent | Small cylinder with a cap, usually on boiler or main pipes | None (self-operating) | Check periodically for leaks or blockages. May need replacement. |
Purge Valve / Drain Cock | Small spigot-like valve, usually near zone valves or on return lines | Wrench or pliers, garden hose | Used for bulk purging of zones. |
Boiler Air Lock Troubleshooting
What if you have purged but still have problems? You might have a boiler air lock. This means a large air bubble is stuck. It completely stops water flow. This can happen in the boiler itself or in a main pipe.
Signs of an Air Lock:
- Boiler runs, pump sounds normal, but no heat anywhere.
- Pressure gauge fluctuates wildly.
- Boiler makes loud noises, like it’s struggling.
Troubleshooting Steps:
- Re-purge System: Sometimes, a second, more thorough purge helps. Follow all steps carefully again. Ensure you open the fill valve fully to create strong flow.
- Increase Pressure Briefly: Try raising the system pressure to 25-30 PSI (temporarily, for a few minutes only, do NOT exceed maximum rated pressure). This higher pressure can sometimes force stubborn air bubbles out. Then, reduce pressure back to normal.
- Cycle Boiler On/Off: Turn the boiler off for 15 minutes. Then turn it back on. The stop-start motion might dislodge air.
- Tap Pipes: Gently tap pipes near cold spots or noisy areas. Use a rubber mallet. This can help move air bubbles.
- Check Automatic Air Vents: If you have an automatic air vent, check it. Sometimes the small cap on top needs to be loose (not fully tightened) for it to work. If it’s old, it might be stuck or faulty. You might hear hissing if it’s working. If it’s leaking or not venting, it may need replacing.
- Examine Hydronic Air Separator: If you have a hydronic air separator, check its automatic vent. Make sure it’s working. These devices are very good at collecting air. But if their vent is stuck, air stays trapped. The hydronic air separator purpose is to make your system more efficient.
- Isolate the Circulator Pump: Air can get trapped right at the circulator pump. This leads to circulator pump air issues. Some pumps have small vents on them. Check your pump’s manual. If you suspect air around the pump, you might need to try and manually vent it if it has that option, or purge the loop it’s on very aggressively.
- Professional Help: If all else fails, call a qualified heating technician. Boiler air lock troubleshooting can be tricky. They have tools and knowledge to fix complex air locks.
Regular Maintenance for an Air-Free System
To avoid future air problems, do some regular checks.
- Annual Purge: Even if you do not have cold spots, a small purge each year is good. Do it before the heating season starts. This cleans out any trapped air.
- Check Pressure Gauge: Look at your pressure gauge regularly. If the pressure drops too much or too often, it can mean a leak. It can also mean air is getting in.
- Inspect Air Vents: Check your automatic air vents. Make sure they are not leaking. Make sure their little cap is loose. A leaking vent means it is failing. It needs replacement.
- Listen for Noises: Pay attention to your heating system. If you start hearing gurgling noise in heating pipes, it is a sign to act.
- Check Expansion Tank: Gently tap your expansion tank. It should sound hollow on the top part. It should sound solid (like water) on the bottom part. If it sounds solid all over, it is full of water. It needs to be serviced or replaced. A bad expansion tank can cause air problems.
Regular care keeps your hydronic system running smoothly. It means you will have fewer cold rooms and lower bills.
Grasping the Principle of Zone-by-Zone Purging
Why do we purge one zone at a time? It is simple physics. When you close all zone valves except one, you force all the water and air to flow through only that one path. This creates a stronger flow. This strong flow pushes air out better.
Think of it like cleaning a pipe. If you have many branches, and you open all of them, the water pressure splits. It becomes weak. It cannot push debris out well. But if you close all branches except one, all the water goes through that one branch. It creates a powerful flush.
The same idea applies to bleeding multiple heating zones. By isolating each zone, you guarantee that the fresh water coming from your fill valve has enough force. It pushes out air trapped in that specific loop of pipes. This ensures a complete hydronic system air removal. If you opened all zones at once, the air might just move around. It would not leave the system.
This method also helps you identify where the air is. If you purge Zone 1 and it becomes hot, but Zone 2 is still cold, you know the air is in Zone 2. It simplifies boiler air lock troubleshooting.
When to Seek Expert Help
While purging is often a DIY task, some issues need a pro.
- Persistent Cold Spots: You have purged several times. Still, some rooms are cold.
- Boiler Malfunctions: Your boiler is not firing. It gives error codes.
- Constant Pressure Loss: Your system loses pressure often. You have to add water a lot. This points to a leak.
- Loud System Noises: Beyond gurgling, if you hear banging or hammering, this could be a serious problem.
- Uncertainty: You are not sure about any step. Or you feel unsafe.
A professional heating technician can use special tools. They can diagnose complex issues. They can fix leaks. They can replace faulty parts. They ensure your heating system is safe and efficient. Do not hesitate to call them if you are stuck.
Frequently Asked Questions (FAQ)
Q1: How often should I purge my boiler system?
A1: It is a good idea to purge your boiler system once a year. Do it before the heating season starts. If you hear gurgling noise in heating pipes, purge it sooner.
Q2: What is the correct pressure for my boiler system?
A2: For a cold system, the pressure is usually between 12-18 PSI (pounds per square inch). For a hot system, it might rise to 20-25 PSI. Always check your boiler’s manual for exact numbers.
Q3: Can I damage my boiler by purging air?
A3: If done correctly, purging is safe. Do not over-pressurize the system. Do not drain too much water. Always turn off the boiler power first. Follow the steps carefully to avoid problems.
Q4: My automatic air vent keeps leaking. What should I do?
A4: A leaking automatic air vent means it is failing. It needs replacement. Call a technician for this. It is a small part, but very important for hydronic system air removal.
Q5: Why is my boiler always running, but the house is cold?
A5: This often means air is trapped in your system. It stops hot water from reaching all zones. This is a classic case of boiler no heat due to air. Purging the system by zone should help.
Q6: Can a faulty expansion tank cause air problems?
A6: Yes, it can. If the expansion tank is bad, it cannot absorb water expansion. This can cause pressure swings. These swings can pull air into the system or keep it trapped.
Q7: Is it normal for some dirty water to come out during purging?
A7: Yes, especially at first. The water might be discolored or contain rust particles. This is normal. Keep purging until the water runs clear.
Q8: My circulator pump is noisy. Is this air?
A8: Yes, a noisy circulator pump often points to circulator pump air issues. Air can make the pump cavitate (struggle to move water). Purging the system, especially the loops around the pump, should fix this. If it persists, the pump itself might be failing.
Purging air from your boiler system with zone valves might seem complex. But by taking it one zone at a time, you can do it. You will enjoy a quieter, warmer, and more efficient home.

My name is Carlos Gadd, and I am the creator of AirPurityGuide.com.. With a passion for footwear, I share my experiences, insights, and expertise about shoes. Through my blog, I aim to guide readers in making informed decisions, finding the perfect pair, and enhancing their footwear knowledge. Join me on this journey to explore everything about shoes!